2 BitStorm 1900 Installation and Testing Elastic Networks
2-56 BitStorm 1900™ Installation and Maintenance Guide 08-01101-01, Rev. 1.50
Step Procedure cont.
Figure 2-3: -48 V DC Fan Tray
3.) Connect power for the 110/220 V AC fan tray.
a.) Connect the power cord to the IEC terminal connection on the
front panel.
b.) Route the other end to a grounded outlet.
NOTE: The power supply for the multiplexer must also be 110 V AC.
Figure 2-4: 110 V AC Fan Tray
!
WARNING: POSSIBLE EQUIPMENT DAMAGE! Be sure
to set the switch on the back panel of the
110/220 V AC fan tray to 115 V for a 110 V AC
connection, and 230 V for a 220 V AC
connection. Failure to do so will pop the fuse
on the front panel.